Electronic supporting informationDescriptionSchematics and photographs of the gas sampling systemBME680 gas sensor specifications and formatResults from a qualitative flow rate testEI 70 eV spectra of α-pinene and 4-bromofluorobenzeneLog-log plot of the time constant against the mass of α-pineneSensitivity and limit of detection for three BME680 sensorsLog-log plot showing the linear range of a BME680 sensorFour repetitions of the 1000 ppb α-pinene calibration testLog-log plot showing the linear range of the TD-GC-MSRepresentative responses for BME680/GC validation studiesValidation of three BME680 sensors against TD-GC-MS for α-pineneCalibrated peaks of a BME680 sensor responseSample correlation matrix comparing the response between four sensors recording three exposures to 200 ppb α-pinene in static argon for continuously acquired dataRelative variation in the responses between four sensors to six concentrations of α-pinene before and after calibrations for continuously acquired dataCalibration protocolAdditional scanning electron micrographs of BME680 gas sensor and EDS spectrum of the active areaComparison of electronic and TD-GC-MS VOC sensingFile formatportable document format (pdf)ZIP fileBME680 calibration testsDescriptionThis dataset contains data for 8 different concentrations of alpha-pinene: 1 ppb, 10 ppb, 25 ppb, 50 ppb, 100 ppb, 200 ppb, 500 ppb, and 1000 ppb. Each concentration was tested in triplicate using three different sensors: TCA0, TCA1, and TCA3. Each concentration run includes three repetitions for each sensor.File formatcomma-separated values (csv)File naming conventionBME680_gas_sensor_[sensor number]_[ISO-UTCdatetime].csvBME continuous runDescriptionThis dataset includes data from a continuous run used for two-point sensor calibration. Data were collected from four sensors, each continuously recording data for 5 different concentrations of alpha-pinene.File formatcomma-separated values (csv)File naming conventionBME680_gas_sensor_[sensor number]_[ISO-UTCdatetime].csvBME validation testsDescriptionThis dataset contains data for 3 concentrations of alpha-pinene, recorded by three sensors: TCA0, TCA1, and TCA3. Each concentration was tested in triplicate.File formatcomma-separated values (csv)File naming conventionBME680_gas_sensor_[sensor number]_[ISO-UTCdatetime].csvGC calibration dataDescriptionThis dataset is organized by concentration of alpha-pinene, including 0.01 ppb, 0.1 ppb, 1 ppb, 10 ppb, 25 ppb, 50 ppb, 100 ppb, and blank tests. The processed data is compiled in an Excel workbook.File formatscomma-separated values (csv) and Open Office XML-based spreadsheet format (xlsx)File naming convention All data: [concentration in ppm]c.csvRegion containing the internal standard molecule: [concentration in ppm]c 174-95.csv Region containing α-pinene molecule fragment 1: [concentration in ppm]c 136-93.csv Region containing α-pinene molecule fragment 2: [concentration in ppm]c 93-77.csv Combined processed data: Peaks all in one.xlsxGC validationDescriptionThis dataset contains data for three concentrations: 30 ppb, 50 ppb, and 100 ppb. Each concentration has two files: one for internal standard results and another for tested alpha-pinene. Each concentration was tested in triplicate. The processed data is compiled in an Excel workbook titled 'Peaks areas'.File formatOpen Office XML-based spreadsheet format (xlsx)File naming convention[concentration in ppm] [repetition] [ISTD|alpha].xlsxCalibration workbookDescriptionThis spreadsheet contains all the calculations for statistical analysis related to calibrationFile formatOpen Office XML-based spreadsheet format (xlsx)File nameCalculation workbook.xlsxBME validation workbookDescriptionThis workbook contains all figures and data analysis related to the BME validation tests.File formatsGraphPad Prism 5-9 Project (pfzx) [closed format] and GraphPad Prism Project (prism) [same data, open format]File nameBME validation workbook.[pfzx|prism]Table of contentsDescriptionThis text for this ZIP file's contentsFile formatrich-text format (rtf)File nameREADME.rtf
- pinene
- gas chromatographic analysis
- Thermal desorption gas chromatography
- electronic sensors
- volatile organic compounds
- metal oxide gas sensors
- real-time monitoring systems
- validation research