The TA Instruments Discovery DMA 850 instrument applies an oscillating force to a material and measures its response; from such experiments, the viscosity (visco-) and stiffness (elastic) of the sample can be calculated. These viscoelastic properties can be related to temperature, time, or frequency. Example applications include using DMA to determine the glass transition of polymers, or the to measure the response of a material to when a force is applied/removed.
→ Temperature range: -80 ºC to +400 ºC
→ Force: 0.1 mN to 18 N
→ Moveable clamp: 0.1 nm resolution over a 25 mm continuous range of travel
→ Clamps:
⇒ Single cantilever.
Sample size: length = 35.5mm, width = <12.75mm, thickness = <5 mm (recommended thickness = 1.75mm)
⇒ Dual cantilever
Sample size: length = 60mm, width = <12.75mm, thickness = <5mm (recommended thickness = 1.75mm)
⇒ 3-point bend
Sample size: length = 60mm, width = <12.5mm, thickness = <7mm
⇒ Shear sandwich
Samples are 2x square pieces with the following size: length and width = 10mm, thickness = <4mm (thickness for measurement is the sum of the two pieces)
⇒ Tension film/fibre
Sample size: length = 5-30mm, width = <6mm, thickness = <2mm
⇒ Compression
Samples are discs with the following size: diameter = 40mm OR 15mm, thickness = <10mm
⇒ Other clamps available = Powder, Submersion film/fibre, Submersion 3-point bend, Humidity furnace for 3-point bend only
Sample sizes can be given upon request
To request training follow the 'website' link. Please note you must have completed the necessary H&S inductions for the Royce Hub Building and L6 laboratories prior to requesting training.
→ Temperature range: -80 ºC to +400 ºC
→ Force: 0.1 mN to 18 N
→ Moveable clamp: 0.1 nm resolution over a 25 mm continuous range of travel
→ Clamps:
⇒ Single cantilever.
Sample size: length = 35.5mm, width = <12.75mm, thickness = <5 mm (recommended thickness = 1.75mm)
⇒ Dual cantilever
Sample size: length = 60mm, width = <12.75mm, thickness = <5mm (recommended thickness = 1.75mm)
⇒ 3-point bend
Sample size: length = 60mm, width = <12.5mm, thickness = <7mm
⇒ Shear sandwich
Samples are 2x square pieces with the following size: length and width = 10mm, thickness = <4mm (thickness for measurement is the sum of the two pieces)
⇒ Tension film/fibre
Sample size: length = 5-30mm, width = <6mm, thickness = <2mm
⇒ Compression
Samples are discs with the following size: diameter = 40mm OR 15mm, thickness = <10mm
⇒ Other clamps available = Powder, Submersion film/fibre, Submersion 3-point bend, Humidity furnace for 3-point bend only
Sample sizes can be given upon request
To request training follow the 'website' link. Please note you must have completed the necessary H&S inductions for the Royce Hub Building and L6 laboratories prior to requesting training.