TY - JOUR
T1 - A computational model for prediction of clot platelet content in flow-diverted intracranial aneurysms
AU - Sarrami-Foroushani, Ali
AU - Lassila, Toni
AU - Hejazi, Seyed Mostafa
AU - Nagaraja, Sanjoy
AU - Bacon, Andrew
AU - Frangi, Alejandro F.
N1 - Funding Information:
A. Sarrami-Foroushani, T. Lassila, and A.F. Frangi were funded by the H2020 Programme project InSilc “In-silico trials for drug-eluting BVS design, development and evaluation” (H2020-SC1-2017-CNECT-2-777119). T. Lassila and A.F. Frangi were funded by the 7th Framework Programme project VPH-DARE@IT “Virtual Physiological Human: DementiA Research Enabled by IT” (FP7-ICT-2011-5.2-601055). A.F. Frangi acknowledges support from the Royal Academy of Engineering under the RAEng Chairs in Emerging Technologies scheme (CiET1919/19).
Funding Information:
A. Sarrami-Foroushani, T. Lassila, and A.F. Frangi were funded by the H2020 Programme project InSilc ?In-silico trials for drug-eluting BVS design, development and evaluation? (H2020-SC1-2017-CNECT-2-777119). T. Lassila and A.F. Frangi were funded by the 7th Framework Programme project VPH-DARE@IT ?Virtual Physiological Human: DementiA Research Enabled by IT? (FP7-ICT-2011-5.2-601055). A.F. Frangi acknowledges support from the Royal Academy of Engineering under the RAEng Chairs in Emerging Technologies scheme (CiET1919/19).
Publisher Copyright:
© 2019 The Authors
PY - 2019/6/25
Y1 - 2019/6/25
N2 - Treatment of intracranial aneurysms with flow-diverting stents is a safe and minimally invasive technique. The goal is stable embolisation that facilitates stent endothelialisation, and elimination of the aneurysm. However, it is not fully understood why some aneurysms fail to develop a stable clot even with sufficient levels of flow reduction. Computational prediction of thrombus formation dynamics can help predict the post-operative response in such challenging cases. In this work, we propose a new model of thrombus formation and platelet dynamics inside intracranial aneurysms. Our novel contribution combines platelet activation and transport with fibrin generation, which is key to characterising stable and unstable thrombus. The model is based on two types of thrombus inside aneurysms: red thrombus (fibrin- and erythrocyte-rich) can be found in unstable clots, while white thrombus (fibrin- and platelet-rich) can be found in stable clots. The thrombus generation model is coupled to a CFD model and the flow-induced platelet index (FiPi) is defined as a quantitative measure of clot stability. Our model is validated against an in vitro phantom study of two flow-diverting stents with different sizing. We demonstrate that our model accurately predicts the lower thrombus stability in the oversized stent scenario. This opens possibilities for using computational simulations to improve endovascular treatment planning and reduce adverse events, such as delayed haemorrhage of flow-diverted aneurysms.
AB - Treatment of intracranial aneurysms with flow-diverting stents is a safe and minimally invasive technique. The goal is stable embolisation that facilitates stent endothelialisation, and elimination of the aneurysm. However, it is not fully understood why some aneurysms fail to develop a stable clot even with sufficient levels of flow reduction. Computational prediction of thrombus formation dynamics can help predict the post-operative response in such challenging cases. In this work, we propose a new model of thrombus formation and platelet dynamics inside intracranial aneurysms. Our novel contribution combines platelet activation and transport with fibrin generation, which is key to characterising stable and unstable thrombus. The model is based on two types of thrombus inside aneurysms: red thrombus (fibrin- and erythrocyte-rich) can be found in unstable clots, while white thrombus (fibrin- and platelet-rich) can be found in stable clots. The thrombus generation model is coupled to a CFD model and the flow-induced platelet index (FiPi) is defined as a quantitative measure of clot stability. Our model is validated against an in vitro phantom study of two flow-diverting stents with different sizing. We demonstrate that our model accurately predicts the lower thrombus stability in the oversized stent scenario. This opens possibilities for using computational simulations to improve endovascular treatment planning and reduce adverse events, such as delayed haemorrhage of flow-diverted aneurysms.
KW - Flow diverter
KW - Intracranial aneurysms
KW - Thrombosis
KW - Computational fluid dynamics
UR - http://www.scopus.com/inward/record.url?scp=85065607949&partnerID=8YFLogxK
U2 - 10.1016/j.jbiomech.2019.04.045
DO - 10.1016/j.jbiomech.2019.04.045
M3 - Article
C2 - 31104921
SN - 0021-9290
VL - 91
SP - 7
EP - 13
JO - Journal of biomechanics
JF - Journal of biomechanics
ER -