Abstract
Due to the limited resolution of Positron Emission Tomography (PET), loss of signal through Partial Volume is significant for small structures. Consequently, Partial Volume Correction (PVC) is often used in PET imaging to recover this lost signal within images. Numerous methods have been proposed, and can be divided in multiple ways. One division is the separation of methods utilising image based segmentation and those that perform image based deconvolution to recover resolution. We propose a new method for PVC, PARtially-Segmented Lucy-Richardson (PARSLR), that combines the image based deconvolution approach of the Lucy-Richardson (LR) Iterative Deconvolution Algorithm with a partial segmentation of homogenous regions. Such an approach is of value where reliable segmentation is possible for part but not all of the image volume or sub-volume. We evaluated the performance of PARSLR with respect to a region-based method (Rousset's method) and a deconvolution voxel-based method (LR) for partial volume correction by comparing how each method behaves in an environment of complete and accurate segmentation, and partial segmentation, on a 3D simulated medial temporal brain area including the hippocampus, as well as on a 2D physical brain phantom. Under complete and accurate segmentation, PARSLR showed agreement in recovery with the other methods. In an environment of partial segmentation, PARSLR recovered the hippocampus intensity with the most accuracy, with Rousset's method showing errors when too many regions were defined. With only one homogeneous background identified, errors were also observed when using Rousset, with the recovered value being smaller than the measured uncorrected data in these particular evaluations. In the 2D measured data for the brain phantom, PARSLR recovered with an error of 0.91%, with LR recovering to 5.23%, for a selected region of cortex. Rousset with a homogeneous background recovered with an error of 6.50%. With the remaining pixels set as individual regions, Rousset's method became ill-conditioned with an error of 157.00%. The method therefore showed good recovery in regions that are only partly segmentable. We propose that the approach is of particular importance for: studies with pathological abnormalities where complete and accurate segmentation across or with a sub-volume of the image volume is challenging; and regions of the brain containing heterogeneous structures which can not be accurately segmented from co-registered images. © 2010 IEEE.
Original language | English |
---|---|
Title of host publication | IEEE Nuclear Science Symposium Conference Record|IEEE Nucl. Sci. Symp. Conf. Rec. |
Pages | 3073-3078 |
Number of pages | 5 |
DOIs | |
Publication status | Published - 2010 |
Event | 2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010 - Knoxville, TN Duration: 1 Jul 2010 → … |
Conference
Conference | 2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010 |
---|---|
City | Knoxville, TN |
Period | 1/07/10 → … |
Keywords
- brain
- deconvolution
- image segmentation
- iterative methods
- medical image processing
- phantoms
- positron emission tomography
- 2D physical brain phantom
- 3D simulated medial temporal brain area
- Lucy-Richardson iterative deconvolution algorithm
- Rousset method
- deconvolution voxel-based method
- hippocampus
- image based deconvolution
- image based segmentation
- partial volume correction
- partially-segmented Lucy-Richardson
- region-based method
- region-based methods
- voxel-based methods