An analytical method to calculate temperatures of components of reverse channel connection to concrete filled steel section under fire conditions

    Research output: Contribution to journalArticlepeer-review

    Original languageEnglish
    Pages (from-to)115-130
    Number of pages16
    JournalFire Safety Journal
    Volume82
    DOIs
    Publication statusPublished - 2016

    Keywords

    • reverse channel connection
    • fire protected connection
    • concrete filled tube
    • heat tranfer
    • temperature calculation
    • analytical model
    • lumped capacitance method
    • heat flux density
    • section factor