Assessing the feasibility of detecting a hemorrhagic type stroke using a 16 channel magnetic induction system

B. Dekdouk, C. Ktistis, D. W. Armitage, A. J. Peyton

    Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

    Abstract

    Magnetic induction tomography (MIT) has been proposed as a possible method for imaging stroke in the human brain. Hemorrhagic stroke is characterized by local blood accumulation in the brain and exhibits a greater change in conductivity with frequency compared to other tissues which is observed in the frequency range of interest [1-10] MHz. In this study, we investigate the feasibility of detecting hemorrhagic stroke using absolute and frequency difference imaging. For this purpose, a model of the head originally obtained from MRI and X-ray data was used, to which a large stroke (50 ml) was added. In addition, a model of a 16 channel circular array MIT system was employed. The received coil induced voltages were computed using a custom eddy current solver, based on the finite difference method. For absolute imaging, the induced voltages at the receiver coils were calculated from various coil combinations at 10 MHz frequency together with anticipated systematic errors and biases (orientation and displacement of the coils, movement of the head). The induced voltage noise due to these systematic inaccuracies was compared with the voltage change due to the stroke. In order to decrease the impact of this noise, frequency difference was also considered, whereby measurements were performed at another frequency (1MHz) and subtracted. Comparison results are presented and a realistic picture is delivered with to regard the required mechanical stability and electronics accuracy for this particular medical application © 2010 IOP Publishing Ltd.
    Original languageEnglish
    Title of host publicationJournal of Physics: Conference Series|J. Phys. Conf. Ser.
    PublisherIOP Publishing Ltd
    Volume224
    DOIs
    Publication statusPublished - 2010
    Event14th International Conference on Electrical Bioimpedance, Held in Conjunction with the 11th Conference on Biomedical Applications of EIT, ICEBI and EIT 2010 - Gainesville, FL
    Duration: 1 Jul 2010 → …

    Conference

    Conference14th International Conference on Electrical Bioimpedance, Held in Conjunction with the 11th Conference on Biomedical Applications of EIT, ICEBI and EIT 2010
    CityGainesville, FL
    Period1/07/10 → …

    Fingerprint

    Dive into the research topics of 'Assessing the feasibility of detecting a hemorrhagic type stroke using a 16 channel magnetic induction system'. Together they form a unique fingerprint.

    Cite this