Assessment of breast density: Reader performance using synthetic mammographic images

Janine Makaronidis, Michael Berks, Jamie Sergeant, Julie Morris, Caroline Boggis, Mary Wilson, Nicky Barr, Sue Astley

    Research output: Chapter in Book/Conference proceedingConference contribution

    Abstract

    The quantity and appearance of dense breast tissue in mammograms is related to the risk of developing breast cancer, the sensitivity of mammographic interpretation, and the likelihood of local recurrence of cancer following surgery. Visual assessment of breast density is widely used, often with readers indicating the percentage of dense tissue in a mammogram. Although real mammograms can be used to investigate intra- and inter-observer variability, ground truth is difficult to ascertain, so to investigate reader accuracy, we created 60 synthetic, mammogram-like images with densities comparable in area to those found in screening. The images contained either a single dense area, multiple or linear densities, or a variable breast size with a single density. The images were randomized and assessed by 9 expert and 6 non-expert readers who marked percentage area of density on a visual analogue scale. Non-expert readers' estimates of percentage area of density were closer to the truth (6-11% mean absolute difference) than the experts' estimates (10-19%). The readers were most accurate when the density formed a single area in the image, and least accurate when the dense area was composed of linear structures. In almost every case, the dense area was overestimated by the expert readers. When experts were ranked according to the degree of overestimation, this broadly reflected their relative performance on real mammograms. © 2011 SPIE.
    Original languageEnglish
    Title of host publicationProgress in Biomedical Optics and Imaging - Proceedings of SPIE|Progr. Biomed. Opt. Imaging Proc. SPIE
    PublisherSPIE
    Volume7966
    ISBN (Print)9780819485083
    DOIs
    Publication statusPublished - 2011
    EventMedical Imaging 2011: Image Perception, Observer Performance, and Technology Assessment - Lake Buena Vista, FL
    Duration: 1 Jul 2011 → …

    Conference

    ConferenceMedical Imaging 2011: Image Perception, Observer Performance, and Technology Assessment
    CityLake Buena Vista, FL
    Period1/07/11 → …

    Keywords

    • Accuracy
    • Breast density
    • Mammogram
    • Perception
    • Visual assessment

    Fingerprint

    Dive into the research topics of 'Assessment of breast density: Reader performance using synthetic mammographic images'. Together they form a unique fingerprint.

    Cite this