Abstract
PURPOSE: To report on the utility of a computer tablet-based method for automated testing of visual acuity in children based on the principles of game design. We describe the testing procedure and present repeatability as well as agreement of the score with accepted visual acuity measures.
DESIGN: Reliability and validity study.
METHODS: Setting: Manchester Royal Eye Hospital Pediatric Ophthalmology Outpatients Department.
PATIENT POPULATION: Total of 112 sequentially recruited patients.
INTERVENTION: For each patient 1 eye was tested with the Mobile Assessment of Vision by intERactIve Computer for Children (MAVERIC-C) system, consisting of a software application running on a computer tablet, housed in a bespoke viewing chamber. The application elicited touch screen responses using a game design to encourage compliance and automatically acquire visual acuity scores of participating patients. Acuity was then assessed by an examiner with a standard chart-based near ETDRS acuity test before the MAVERIC-C assessment was repeated.
MAIN OUTCOME MEASURE: Reliability of MAVERIC-C near visual acuity score and agreement of MAVERIC-C score with near ETDRS chart for visual acuity.
RESULTS: Altogether, 106 children (95%) completed the MAVERIC-C system without assistance. The vision scores demonstrated satisfactory reliability, with test-retest VA scores having a mean difference of 0.001 (SD ±0.136) and limits of agreement of 2 SD (LOA) of ±0.267. Comparison with the near EDTRS chart showed agreement with a mean difference of -0.0879 (±0.106) with LOA of ±0.208.
CONCLUSIONS: This study demonstrates promising utility for software using a game design to enable automated testing of acuity in children with ophthalmic disease in an objective and accurate manner.
Original language | English |
---|---|
Pages (from-to) | 223-227 |
Number of pages | 5 |
Journal | American journal of ophthalmology |
Volume | 170 |
Early online date | 18 Aug 2016 |
DOIs | |
Publication status | Published - Oct 2016 |
Fingerprint
Dive into the research topics of 'Automated Measurement of Visual Acuity in Pediatric Ophthalmic Patients Using Principles of Game Design and Tablet Computers'. Together they form a unique fingerprint.Impacts
-
Smart inhaler improves adherence to treatment for children with asthma
Aslam, T. (Participant), Murray, C. (Participant), (Participant) & Murray, I. (Participant)
Impact: Health and wellbeing