TY - JOUR
T1 - Benchmarking LES with wall-functions and RANS for fatigue problems in thermal–hydraulics systems
AU - Tunstall, R.
AU - Laurence, D.
AU - Prosser, R.
AU - Skillen, A.
PY - 2016/11/1
Y1 - 2016/11/1
N2 - In assessing whether nuclear plant components such as T-Junctions are likely to suffer thermal fatigue problems in service, CFD techniques need to provide accurate predictions for wall temperature fluctuations. Though it has been established that this is within the capabilities of wall-resolved LES, its high computational cost has prevented widespread usage in industry. In the present paper the suitability of LES with blended wall-functions, that allow the first cell to be placed in any part of the boundary layer, is assessed. Numerical results for the flows through a 90° pipe bend and a T-Junction are compared against experimental data. Both test cases contain areas where equilibrium laws are violated in practice. It is shown that reducing the first cell wall spacing improves agreement with experimental data by limiting the extent from the wall in which the solution is constrained to an equilibrium law. The LES with wall-function approach consistently overpredicts the near-wall temperature fluctuations in the T-Junction, suggesting that it can be considered as a conservative approach. We also benchmark a range of low-Re RANS models. EBRSM predictions for the 90° pipe bend are in significantly better agreement with experimental data than those from the other models. There are discrepancies from all RANS models in the case of the T-Junction.
AB - In assessing whether nuclear plant components such as T-Junctions are likely to suffer thermal fatigue problems in service, CFD techniques need to provide accurate predictions for wall temperature fluctuations. Though it has been established that this is within the capabilities of wall-resolved LES, its high computational cost has prevented widespread usage in industry. In the present paper the suitability of LES with blended wall-functions, that allow the first cell to be placed in any part of the boundary layer, is assessed. Numerical results for the flows through a 90° pipe bend and a T-Junction are compared against experimental data. Both test cases contain areas where equilibrium laws are violated in practice. It is shown that reducing the first cell wall spacing improves agreement with experimental data by limiting the extent from the wall in which the solution is constrained to an equilibrium law. The LES with wall-function approach consistently overpredicts the near-wall temperature fluctuations in the T-Junction, suggesting that it can be considered as a conservative approach. We also benchmark a range of low-Re RANS models. EBRSM predictions for the 90° pipe bend are in significantly better agreement with experimental data than those from the other models. There are discrepancies from all RANS models in the case of the T-Junction.
UR - http://www.scopus.com/inward/record.url?scp=84989871454&partnerID=8YFLogxK
U2 - 10.1016/j.nucengdes.2016.08.022
DO - 10.1016/j.nucengdes.2016.08.022
M3 - Article
AN - SCOPUS:84989871454
SN - 0029-5493
VL - 308
SP - 170
EP - 181
JO - Nuclear Engineering and Design
JF - Nuclear Engineering and Design
ER -