TY - JOUR
T1 - Clinical evaluation of a resorbable wrap-around implant as an alternative to nerve repair: A prospective, assessor-blinded, randomised clinical study of sensory, motor and functional recovery after peripheral nerve repair
AU - Åberg, Maria
AU - Ljungberg, Christina
AU - Edin, Ellenor
AU - Millqvist, Helena
AU - Nordh, Erik
AU - Theorin, Anna
AU - Terenghi, Giorgio
AU - Wiberg, Mikael
PY - 2009/11
Y1 - 2009/11
N2 - Peripheral nerve injures are common and often result in impaired functional recovery. The majority of injuries involve the arm and/or the hand. The traditional treatment for peripheral nerve injuries is repair by using microsurgical techniques, either by primary nerve suture or nerve graft, but research to find more successful methods that could improve recovery is ongoing. Tubulisation has been investigated by several authors and is suggested as an alternative to microsurgical techniques. The resorbable poly[(R)-3-hydroxybutyrate] (PHB) is one of the materials that has been previously tested experimentally. In this prospective, randomised, assessor-blinded clinical study, PHB was investigated as an alternative to epineural suturing in the treatment of peripheral nerve injuries at the wrist/forearm level of the arm. Twelve patients, with a complete, common, sharp injury of the median and/or ulnar nerve at the wrist/forearm level, were treated by either using PHB or microsurgical epineural end-to-end suturing. All patients were assessed using a battery of tests, including evaluation of functional, sensory and motor recovery by means of clinical, neurophysiological, morphological and physiological evaluations at 2 weeks and 3, 6, 9, 12 and 18 months after surgery. No adverse events or complications considered as product related were reported, and thus PHB can be regarded as a safe alternative for microsurgical epineural suturing. The majority of the methods in the test battery showed no significant differences between the treatment groups, but one should consider that the study involved a limited number of patients and a high variability was reported for the evaluating techniques. However, sensory recovery, according to the British Medical Research Council score and parts of the manual muscle test, suggested that treating with PHB may be advantageous as compared to epineural suturing. This, however, should be confirmed by large-scale efficacy studies. © 2008 British Association of Plastic, Reconstructive and Aesthetic Surgeons.
AB - Peripheral nerve injures are common and often result in impaired functional recovery. The majority of injuries involve the arm and/or the hand. The traditional treatment for peripheral nerve injuries is repair by using microsurgical techniques, either by primary nerve suture or nerve graft, but research to find more successful methods that could improve recovery is ongoing. Tubulisation has been investigated by several authors and is suggested as an alternative to microsurgical techniques. The resorbable poly[(R)-3-hydroxybutyrate] (PHB) is one of the materials that has been previously tested experimentally. In this prospective, randomised, assessor-blinded clinical study, PHB was investigated as an alternative to epineural suturing in the treatment of peripheral nerve injuries at the wrist/forearm level of the arm. Twelve patients, with a complete, common, sharp injury of the median and/or ulnar nerve at the wrist/forearm level, were treated by either using PHB or microsurgical epineural end-to-end suturing. All patients were assessed using a battery of tests, including evaluation of functional, sensory and motor recovery by means of clinical, neurophysiological, morphological and physiological evaluations at 2 weeks and 3, 6, 9, 12 and 18 months after surgery. No adverse events or complications considered as product related were reported, and thus PHB can be regarded as a safe alternative for microsurgical epineural suturing. The majority of the methods in the test battery showed no significant differences between the treatment groups, but one should consider that the study involved a limited number of patients and a high variability was reported for the evaluating techniques. However, sensory recovery, according to the British Medical Research Council score and parts of the manual muscle test, suggested that treating with PHB may be advantageous as compared to epineural suturing. This, however, should be confirmed by large-scale efficacy studies. © 2008 British Association of Plastic, Reconstructive and Aesthetic Surgeons.
KW - Biodegradable polymeric nerve conduit
KW - Peripheral nerve repair
KW - Randomised clinical trial
U2 - 10.1016/j.bjps.2008.06.041
DO - 10.1016/j.bjps.2008.06.041
M3 - Article
SN - 1748-6815
VL - 62
SP - 1503
EP - 1509
JO - Journal of Plastic, Reconstructive and Aesthetic Surgery
JF - Journal of Plastic, Reconstructive and Aesthetic Surgery
IS - 11
ER -