Abstract
Objective: To measure the degrees of conversion (DC), conversion kinetics, and the effect of post-irradiation time on rapid photo-polymerized bulk-fill resin composites under conditions equivalent to clinical depths of 1 and 4 mm. Methods: 36 specimens (n = 3), based on two resin composites incorporating PowerCure rapid-polymerization technology in two consistencies (PFill; PFlow) and two comparators with matching consistencies (Eceram; EFlow), were investigated from the same manufacturer (Ivoclar AG, Liechtenstein). Specimens were prepared within 4 mm diameter cylindrical molds, of either 1 mm or 4 mm depths respectively, to simulate near-surface and deep locations in a bulk-fill restoration. The independent variables in this study were: materials, thickness and time. Two high irradiance polymerization protocols were utilized for PowerCure materials: 2000 and 3050 mW/cm 2 for 5 and 3 s, respectively. A standard (1200 mW/cm 2) polymerization protocol was used with control materials. FTIR was utilized to measure DC in real-time for 24 h post-irradiation. The data were analyzed using Welch's-ANOVA, Games-Howell post-hoc test, kinetic dual-exponential sum function and independent sample t-tests (p = 0.05). Results: The DC of the materials ranged between 44.7–59.0 % after 5 min, which increased after 24 h reaching 55.7–71.0 % (p < 0.05). Specimen thickness did not influence the overall DC. At 5 min, the highest DC was shown in EFlow. But PFlow, irradiated for 3 s and 5 s exhibited comparable results (p > 0.05). PFill composite irradiated with the 3 s and 5 s protocols did not differ from ECeram (p > 0.05). Specimen thickness and material viscosity affected polymerization kinetics and rate of polymerization (RP max). Faster polymerization occurred in 1 mm specimens (except PFill-5 s and ECeram). PFill and PFlow exhibited faster conversion than the controls. RP max varied across the specimen groups between 4.3–8.8 %/s with corresponding DC RPmax between 22.2–45.3 %. Significance: Polymerization kinetics and RP max were influenced by specimen thickness and material viscosity. PFill and PFlow materials produced an overall comparable conversion at 5 min and 24 h post-irradiation, despite the ultra-short irradiation times, throughout the 4 mm specimen thickness.
Original language | English |
---|---|
Pages (from-to) | 1266-1274 |
Number of pages | 9 |
Journal | Dental Materials |
Volume | 36 |
Issue number | 10 |
Early online date | 12 Aug 2020 |
DOIs | |
Publication status | Published - 1 Oct 2020 |