TY - JOUR
T1 - Dose specification for hippocampal sparing whole brain radiotherapy (HS WBRT)
T2 - Considerations from the UK HIPPO trial QA programme
AU - Megias, Daniel
AU - Phillips, Mark
AU - Clifton-Hadley, Laura
AU - Harron, Elizabeth
AU - Eaton, David J.
AU - Sanghera, Paul
AU - Whitfield, Gillian
PY - 2017
Y1 - 2017
N2 - Objective: The HIPPO trial is a UK randomized Phase II trial of hippocampal sparing (HS) vs conventional wholebrain radiotherapy after surgical resection or radiosurgery in patients with favourable prognosis with 1-4 brain metastases. Each participating centre completed a planning benchmark case as part of the dedicated radiotherapy trials quality assurance programme (RTQA), promoting the safe and effective delivery of HS intensity-modulated radiotherapy (IMRT) in a multicentre trial setting. Methods: Submitted planning benchmark cases were reviewed using visualization for radiotherapy software (VODCA) evaluating plan quality and compliance in relation to the HIPPO radiotherapy planning and delivery guidelines. Results: Comparison of the planning benchmark data highlighted a plan specified using dose to medium as an outlier by comparison with those specified using dose to water. Further evaluation identified that the reported plan statistics for dose to medium were lower as a result of the dose calculated at regions of PTV inclusive of bony cranium being lower relative to brain. Conclusion: Specification of dose to water or medium remains a source of potential ambiguity and it is essential that as part of a multicentre trial, consideration is given to reported differences, particularly in the presence of bone. Evaluation of planning benchmark data as part of an RTQA programme has highlighted an important feature of HS IMRT dosimetry dependent on dose being specified to water or medium, informing the development and undertaking of HS IMRT as part of the HIPPO trial. Advances in knowledge: The potential clinical impact of differences between dose to medium and dose to water are demonstrated for the first time, in the setting of HS whole-brain radiotherapy.
AB - Objective: The HIPPO trial is a UK randomized Phase II trial of hippocampal sparing (HS) vs conventional wholebrain radiotherapy after surgical resection or radiosurgery in patients with favourable prognosis with 1-4 brain metastases. Each participating centre completed a planning benchmark case as part of the dedicated radiotherapy trials quality assurance programme (RTQA), promoting the safe and effective delivery of HS intensity-modulated radiotherapy (IMRT) in a multicentre trial setting. Methods: Submitted planning benchmark cases were reviewed using visualization for radiotherapy software (VODCA) evaluating plan quality and compliance in relation to the HIPPO radiotherapy planning and delivery guidelines. Results: Comparison of the planning benchmark data highlighted a plan specified using dose to medium as an outlier by comparison with those specified using dose to water. Further evaluation identified that the reported plan statistics for dose to medium were lower as a result of the dose calculated at regions of PTV inclusive of bony cranium being lower relative to brain. Conclusion: Specification of dose to water or medium remains a source of potential ambiguity and it is essential that as part of a multicentre trial, consideration is given to reported differences, particularly in the presence of bone. Evaluation of planning benchmark data as part of an RTQA programme has highlighted an important feature of HS IMRT dosimetry dependent on dose being specified to water or medium, informing the development and undertaking of HS IMRT as part of the HIPPO trial. Advances in knowledge: The potential clinical impact of differences between dose to medium and dose to water are demonstrated for the first time, in the setting of HS whole-brain radiotherapy.
UR - http://www.scopus.com/inward/record.url?scp=85014543145&partnerID=8YFLogxK
U2 - 10.1259/bjr.20160829
DO - 10.1259/bjr.20160829
M3 - Article
AN - SCOPUS:85014543145
SN - 0007-1285
VL - 90
JO - British Journal of Radiology
JF - British Journal of Radiology
IS - 1071
M1 - 20160829
ER -