    Abstract

    In this paper, 3D-electrode pixel detectors are described, in which the bias electrode systems have additional elements. Adding resistors between the bias supply line and each bias electrode together with a signal electrode readout that can measure pulse heights of both polarities could simultaneously provide lower capacitance and improved spatial resolution in both directions. A separate paper ("Dual-readout-strip/pixel systems") covers an alternative-pixels with an added strip readout in one direction which could be used with either planar or 3D-electrodes, and could simultaneously provide a fast trigger and significantly increase the spatial resolution in both directions. © 2008.
    Original languageEnglish
    Pages (from-to)332-338
    Number of pages6
    JournalNuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
    Volume594
    Issue number3
    DOIs
    Publication statusPublished - 11 Sept 2008

    Keywords

    • 3D silicon detectors
    • 3D silicon sensors
    • Detector readout
    • Detectors
    • Pixel detectors
    • Radiation detectors

    Fingerprint

    Dive into the research topics of 'Dual readout: 3D direct/induced-signals pixel systems'. Together they form a unique fingerprint.