Skip to main navigation Skip to search Skip to main content

Electrohydrodynamic coating of metal with nano-sized hydroxyapatite

  • Xiang Li
  • , J. Huang
  • , Z. Ahmad
  • , Mohan Edirisinghe

Research output: Contribution to journal › Article › peer-review

Abstract

Electrohydrodynamic spray deposition of a hydroxyapatite (HA) suspension consisting of nano-particles has been used to create a hydroxyapatite coating comprising of nanostructured surface topography. Preliminary coating experiments were carried out on an Al substrate and 30 s was found to be the most appropriate coating time. HA coating on titanium for this duration was found to be well-bonded to the substrate after heat-treatment. A thickness of 2 μm was achieved in 30 s and formation of a bone-like apatite on the surface was detected after incubation of the heat-treated coated Ti in simulated body fluid. Therefore, we have uncovered a new procedure by which nano-biomaterials can be deposited on real orthopedic substrates to prepare bioactive thin coatings in a simple and easy manner.
Original languageEnglish
Pages (from-to)335-346
Number of pages12
JournalBio-medical materials and engineering
Volume17
Issue number6
Publication statusPublished - 2007

Keywords

  • Coating
  • Electrohydrodynamic
  • Nano-hydroxyapatite
  • Titanium

Fingerprint

Dive into the research topics of 'Electrohydrodynamic coating of metal with nano-sized hydroxyapatite'. Together they form a unique fingerprint.