Abstract
There is currently significant interest in offshore wind turbines up to 5 MW. One of the preferred options is doubly fed slip-ring generators. Turbine manufacturers have proposed an operating scheme for low speeds that is claimed to improve the overall energy extraction from the wind. This paper aims to examine the performance benefits for this new operational mode on a small experimental rig, confirmed by simulation, and to provide a fundamental understanding of the differences in the generator operation in both modes. This paper develops analytical steady-state models to provide this insight and correlates the operating performance with a dynamic real-time generator control scheme and experimental results obtained from a laboratory test machine. A theoretical study on a 2-MW commercial turbine is also undertaken. © 2006 IEEE.
| Original language | English |
|---|---|
| Pages (from-to) | 1421-1428 |
| Journal | IEEE Transactions on Industry Applications |
| Volume | 42 |
| Issue number | 6 |
| DOIs | |
| Publication status | Published - Nov 2006 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Doubly fed (DF) generator
- Induction generator (IG)
- Slip-energy recovery
- Wind-turbine generator
Fingerprint
Dive into the research topics of 'Improved energy conversion for doubly fed wind generators'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver