TY - JOUR
T1 - International survey of orthokeratology contact lens fitting
AU - Morgan, P.B.
AU - Efron, N.
AU - Woods, C.A.
AU - Santodomingo-Rubido, J.
PY - 2019
Y1 - 2019
N2 - Purpose: To determine the extent of orthokeratology (OK) contact lens fitting worldwide and to characterize associated demographics and fitting patterns. Methods: Survey forms were sent to contact lens fitters in 45 countries between January and March every year for 14 consecutive years (2004 – 2017, inclusive). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Results: Data were obtained for 295,044 contact lens fits, of which 2,702 were with OK lenses and 292,342 were with other lens types (non-OK). Overall, OK lenses represented 1.2% of all contact lens fits, with significant differences between nations (p < 0.0001), ranging from no fits recorded in Brazil, Egypt, Indonesia, Iran, Lithuania, Nepal and the United Arab Emirates, to 6.0% in The Netherlands. There has been a slight overall increase in OK lens fitting over the survey period (p < 0.0001). OK lenses were fitted to younger persons (OK, 25.0 ± 12.8 years vs. non-OK, 39.8 ± 14.9 years) (p < 0.0001). A higher proportion of males (55%) were fitted with OK lenses versus non-OK lenses (30%) (p < 0.0009). There was a skewed distribution towards OK lenses being fit with higher oxygen permeable materials (p < 0.0001) and on a planned replacement basis (p < 0.0001). Conclusions: OK contact lens prescribing is a niche activity, with this lens type typically being fitted in high oxygen permeable materials on a planned replacement basis to younger males. The slightly increasing rate of OK fitting, albeit at a very low level, may be attributed to practitioner interest in the reported myopia control properties of this lens type.
AB - Purpose: To determine the extent of orthokeratology (OK) contact lens fitting worldwide and to characterize associated demographics and fitting patterns. Methods: Survey forms were sent to contact lens fitters in 45 countries between January and March every year for 14 consecutive years (2004 – 2017, inclusive). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Results: Data were obtained for 295,044 contact lens fits, of which 2,702 were with OK lenses and 292,342 were with other lens types (non-OK). Overall, OK lenses represented 1.2% of all contact lens fits, with significant differences between nations (p < 0.0001), ranging from no fits recorded in Brazil, Egypt, Indonesia, Iran, Lithuania, Nepal and the United Arab Emirates, to 6.0% in The Netherlands. There has been a slight overall increase in OK lens fitting over the survey period (p < 0.0001). OK lenses were fitted to younger persons (OK, 25.0 ± 12.8 years vs. non-OK, 39.8 ± 14.9 years) (p < 0.0001). A higher proportion of males (55%) were fitted with OK lenses versus non-OK lenses (30%) (p < 0.0009). There was a skewed distribution towards OK lenses being fit with higher oxygen permeable materials (p < 0.0001) and on a planned replacement basis (p < 0.0001). Conclusions: OK contact lens prescribing is a niche activity, with this lens type typically being fitted in high oxygen permeable materials on a planned replacement basis to younger males. The slightly increasing rate of OK fitting, albeit at a very low level, may be attributed to practitioner interest in the reported myopia control properties of this lens type.
KW - contact lenses
KW - fitting
KW - orthokeratology
KW - survey
U2 - 10.1016/j.clae.2018.11.005
DO - 10.1016/j.clae.2018.11.005
M3 - Article
AN - SCOPUS:85056464380
SN - 1367-0484
JO - Contact Lens and Anterior Eye
JF - Contact Lens and Anterior Eye
ER -