Iron kinetics: Modelling and parameter estimation in normal and anemic states

C. Berzuini, P. Colli Franzone, M. Stefanelli, C. Viganotti

    Research output: Contribution to journalArticlepeer-review

    Abstract

    A seven-compartment model for ferrokinetics is presented here and an optimization algorithm of the gradient type for the evaluation of its parameters is described. The reliability of the parameter estimates is tested calculating marginal standard deviations by computing the information matrix through the sensitivity coefficients. The reality and clinical implications of the model are discussed and the values ofits parameters in normal and anemic states speculated upon. © 1978.
    Original languageEnglish
    Pages (from-to)209-227
    Number of pages18
    JournalComputers and Biomedical Research
    Volume11
    Issue number3
    Publication statusPublished - Jun 1978

    Keywords

    • Information matrix
    • Sensitivity coefficients
    • Maximum likelihood estimation
    • Anemia
    • Hypochromic
    • metabolism
    • diagnosis
    • Iron
    • Models
    • Biological

    Fingerprint

    Dive into the research topics of 'Iron kinetics: Modelling and parameter estimation in normal and anemic states'. Together they form a unique fingerprint.

    Cite this