Abstract
This paper explores the operation of doubly fed induction generator (DFIG) under unbalanced supply conditions. Supply unbalance generally has a negative effect on induction machine operation, resulting in increased Joule loss and pulsating torques. The aim of this work is to quantify the effect that stator and/or rotor supply unbalance has on these aspects of DFIG performance. © 2008 IEEE.
Original language | English |
---|---|
Title of host publication | 2008 IEEE International Conference on Sustainable Energy Technologies, ICSET 2008|IEEE Int. Conf. Sustainable Energy Technol., ICSET |
Pages | 328-333 |
Number of pages | 5 |
DOIs | |
Publication status | Published - 2008 |
Event | 2008 IEEE International Conference on Sustainable Energy Technologies, ICSET 2008 - Singapore Duration: 1 Jul 2008 → … |
Conference
Conference | 2008 IEEE International Conference on Sustainable Energy Technologies, ICSET 2008 |
---|---|
City | Singapore |
Period | 1/07/08 → … |