Abstract
This paper explores the operation of doubly fed induction generator (DFIG) under unbalanced supply conditions. Supply unbalance generally has a negative effect on induction machine operation, resulting in increased Joule loss and pulsating torques. The aim of this work is to quantify the effect that stator and/or rotor supply unbalance has on these aspects of DFIG performance. © 2008 IEEE.
| Original language | English |
|---|---|
| Title of host publication | 2008 IEEE International Conference on Sustainable Energy Technologies, ICSET 2008|IEEE Int. Conf. Sustainable Energy Technol., ICSET |
| Pages | 328-333 |
| Number of pages | 5 |
| DOIs | |
| Publication status | Published - 2008 |
| Event | 2008 IEEE International Conference on Sustainable Energy Technologies, ICSET 2008 - Singapore Duration: 1 Jul 2008 → … |
Conference
| Conference | 2008 IEEE International Conference on Sustainable Energy Technologies, ICSET 2008 |
|---|---|
| City | Singapore |
| Period | 1/07/08 → … |