Low cycle fatigue behaviour of APL 5L X65 pipeline steel at room temperature.

O. Fatoba, R. Akid

    Research output: Contribution to journalArticlepeer-review

    Abstract

    In this study, the low-cycle fatigue (LCF) behaviour of API 5L X65 pipeline steel was investigated under fully-reversed strain controlled conditions at room temperature. The companion test method was used to obtain the cyclic stress-strain response curve with strain amplitudes ranging between 0.3% and 1.2%. Results showed that the steel undergoes both cyclic hardening and softening behaviour depending on the strain amplitude. At relatively lower strain amplitudes (0.3 - 0.8%), only cyclic softening was observed whereas at higher strain amplitudes, softening behaviour was preceded by significant hardening in the first few cycles. Based on the cyclic half-life results, the LCF life decreased while stress amplitude and plastic strain amplitude increased with total strain amplitude. Furthermore, analysis of stabilised hysteresis loops showed that the steel exhibits non-Masing behaviour. Complimentary scanning electron microscopy examinations were also carried out on fracture surfaces to reveal dominant damage mechanisms during crack initiation, propagation and fracture.
    Original languageEnglish
    Pages (from-to)279-286
    Number of pages7
    JournalProcedia Engineering
    Volume74
    DOIs
    Publication statusPublished - 2014

    Keywords

    • Cyclic hardening
    • Cyclic softening
    • Cyclic stress-strain curve
    • Fracture
    • Low cycle fatigue
    • Non-masing
    • X65 steel

    Fingerprint

    Dive into the research topics of 'Low cycle fatigue behaviour of APL 5L X65 pipeline steel at room temperature.'. Together they form a unique fingerprint.