Operation of a vertical thermosiphon reboiler experimental facility at reduced pressures

H. R S Benson, T. Schnabel, D. R. Webb, P. J. Heggs, Richard Griffiths

    Research output: Contribution to journalArticlepeer-review

    Abstract

    Experimental data were obtained for the evaporation of water in a vertical thermosiphon reboiler having 50 tubes of 3 m length and 25.4 mm outer diameter. The effect of step changes in heat load was noted for operation over a pressure range from 0.2 to 1.0 bar. The reboiler behaviour exhibited three 'operational modes', and a definite transitional point that is independent of process pressure was observed between operational modes one and two. The influence of reduced pressures on the vertical thermosiphon reboiler sub-cooled heating length was significant. Overall heat transfer coefficients at 0.2 bar were about 60% of those at 1.0 bar and circulation rates were approximately halved. Two important considerations for the reboiler operation analysis were (a) the possible non-uniform behaviour of the reboiler tubes and (b) the change of phase and processes occurring on the reboiler shell as well as the tube side. © 2004 Institution of Chemical Engineers.
    Original languageEnglish
    Pages (from-to)445-456
    Number of pages11
    JournalChemical Engineering Research and Design
    Volume82
    Issue number4
    DOIs
    Publication statusPublished - Apr 2004

    Keywords

    • Instability
    • Low pressure
    • Reboiler
    • Vertical thermosiphon

    Fingerprint

    Dive into the research topics of 'Operation of a vertical thermosiphon reboiler experimental facility at reduced pressures'. Together they form a unique fingerprint.

    Cite this