T1 - Quantitating the effect of prosthesis design on femoral remodeling using high-resolution region-free densitometric analysis (DXA-RFA)
AU - Farzi, Mohsen
AU - Morris, Richard M.
AU - Penny, Jeannette
AU - Yang, Lang
AU - Pozo, Jose M.
AU - Overgaard, Søren
AU - Frangi, Alejandro F.
AU - Wilkinson, Jeremy Mark
N1 - Funding Information:
This study was funded internally by the University of Sheffield. M Farzi was funded through a PhD Fellowship from the MRC Arthritis Research-UK Center for Integrated research into Musculoskeletal Ageing (CIMA). The funding source played no role in the investigation.
Publisher Copyright:
© 2017 The Authors Journal of Orthopaedic Research published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society
PY - 2017/10
Y1 - 2017/10
N2 - Dual energy X-ray absorptiometry (DXA) is the reference standard method used to study bone mineral density (BMD) after total hip arthroplasty (THA). However, the subtle, spatially complex changes in bone mass due to strain-adaptive bone remodeling relevant to different prosthesis designs are not readily resolved using conventional DXA analysis. DXA region free analysis (DXA RFA) is a novel computational image analysis technique that provides a high-resolution quantitation of periprosthetic BMD. Here, we applied the technique to quantitate the magnitude and areal size of periprosthetic BMD changes using scans acquired during two previous randomized clinical trials (2004 to 2009); one comparing three cemented prosthesis design geometries, and the other comparing a hip resurfacing versus a conventional cementless prosthesis. DXA RFA resolved subtle differences in magnitude and area of bone remodeling between prosthesis designs not previously identified in conventional DXA analyses. A mean bone loss of 10.3%, 12.1%, and 11.1% occurred for the three cemented prostheses within a bone area fraction of 14.8%, 14.4%, and 6.2%, mostly within the lesser trochanter (p < 0.001). For the cementless prosthesis, a diffuse pattern of bone loss (−14.3%) was observed at the shaft of femur in a small area fraction of 0.6% versus no significant bone loss for the hip resurfacing prosthesis (p < 0.001). BMD increases were observed consistently at the greater trochanter for all prostheses except the hip-resurfacing prosthesis, where BMD increase was widespread across the metaphysis (p < 0.001). DXA RFA provides high-resolution insights into the effect of prosthesis design on the local strain environment in bone.
AB - Dual energy X-ray absorptiometry (DXA) is the reference standard method used to study bone mineral density (BMD) after total hip arthroplasty (THA). However, the subtle, spatially complex changes in bone mass due to strain-adaptive bone remodeling relevant to different prosthesis designs are not readily resolved using conventional DXA analysis. DXA region free analysis (DXA RFA) is a novel computational image analysis technique that provides a high-resolution quantitation of periprosthetic BMD. Here, we applied the technique to quantitate the magnitude and areal size of periprosthetic BMD changes using scans acquired during two previous randomized clinical trials (2004 to 2009); one comparing three cemented prosthesis design geometries, and the other comparing a hip resurfacing versus a conventional cementless prosthesis. DXA RFA resolved subtle differences in magnitude and area of bone remodeling between prosthesis designs not previously identified in conventional DXA analyses. A mean bone loss of 10.3%, 12.1%, and 11.1% occurred for the three cemented prostheses within a bone area fraction of 14.8%, 14.4%, and 6.2%, mostly within the lesser trochanter (p < 0.001). For the cementless prosthesis, a diffuse pattern of bone loss (−14.3%) was observed at the shaft of femur in a small area fraction of 0.6% versus no significant bone loss for the hip resurfacing prosthesis (p < 0.001). BMD increases were observed consistently at the greater trochanter for all prostheses except the hip-resurfacing prosthesis, where BMD increase was widespread across the metaphysis (p < 0.001). DXA RFA provides high-resolution insights into the effect of prosthesis design on the local strain environment in bone.
KW - bone mineral density
KW - dual energy X-ray absorptiometry (DXA)
KW - false discovery rate (FDR)
KW - hip arthroplasty
KW - strain-adaptive bone remodeling
UR - http://www.scopus.com/inward/record.url?scp=85017562743&partnerID=8YFLogxK
U2 - 10.1002/jor.23536
DO - 10.1002/jor.23536
M3 - Article
C2 - 28169450
AN - SCOPUS:85017562743
SN - 0736-0266
VL - 35
SP - 2203
EP - 2210
JO - Journal of Orthopaedic Research
JF - Journal of Orthopaedic Research
IS - 10
ER -