Skip to main navigation Skip to search Skip to main content

Quantitative comparison of static perimetric strategies in early glaucoma: Test-retest variability

  • P. G D Spry
  • , D. B. Henson
  • , J. M. Sparrow
  • , R. V. North

    Research output: Contribution to journalArticlepeer-review

    Abstract

    Purpose: The aim of this study is to describe and compare test-retest variability of threshold-related suprathreshold and threshold examination strategies. Methods: Threshold-related suprathreshold and FASTPAC threshold central visual field examinations were performed twice (test and retest) within a 4-week period on 322 subjects with early to moderate primary open-angle glaucoma and glaucoma suspects. For both strategies, defects were quantified by a count, or score, of the number of defective locations within the field as a whole and by hemifield, thereby providing a simple measure of defect extent. This quantification was obtained for the suprathreshold strategy at three suprathreshold increments (5, 8, and 12 dB) and for the full threshold strategy at two levels of pattern deviation probability, although absolute full threshold defect depth was not considered. Mean test-retest score differences and spread of score differences were used to describe variability. An index of relative variability was used to compare the two visual field examination strategies. Results: Marked degrees of defect extent variability were found to exist in both suprathreshold and FASTPAC examination strategies. In general, the suprathreshold strategy exhibited lower test-retest variability of defect extent than the FASTPAC strategy. Suprathreshold test variability was dependent on the suprathreshold increment. FASTPAC examination variability was independent of defect depth when analyzed on the basis of pattern deviation probability values and was also found to be independent of the area of visual field loss. Conclusions: Suprathreshold examination techniques may provide a reliable perimetric alternative to thresholding strategies for monitoring individuals with early and moderate glaucoma, although they may not be suitable for individuals with advanced glaucomatous visual field loss.
    Original languageEnglish
    Pages (from-to)247-253
    Number of pages6
    JournalJournal of Glaucoma
    Volume9
    Issue number3
    Publication statusPublished - 2000

    Keywords

    • Glaucoma
    • Perimetry
    • Variability
    • Visual fields

    Fingerprint

    Dive into the research topics of 'Quantitative comparison of static perimetric strategies in early glaucoma: Test-retest variability'. Together they form a unique fingerprint.

    Cite this