Quantitative evaluation of angular defects by pulsed eddy current thermography

  • Ilham Zainal Abidin
  • , Gui Yun Tian
  • , John W Wilson
  • , Suixian Yang
  • , Darryl Almond

    Research output: Contribution to journalArticlepeer-review

    Abstract

    Pulsed eddy current (PEC) thermography employs a combination of PEC and thermographic non-destructive testing (NDT) techniques. This study considers the capabilities of PEC thermography for obtaining quantitative information about cracks set at an angle to the surface. The investigation is implemented by simulating the transient thermal distribution for angular slots, via time-stepping 3D finite element analysis (FEA), with the experimental work undertaken for verification. A slope inclination feature of the transient temperature distribution has been extracted and presented for estimating the angle of slots that is independent of slot depth and length inside the sample. With the identification of the slot angle, quantification of the length/depth of the slot inside the sample can then be made through a maximum temperature amplitude feature. Experimental studies have been undertaken for evaluation of the numerical simulation and transient feature extraction methods.
    Original languageUndefined
    Pages (from-to)537-546
    Number of pages10
    JournalNDT and E International
    Volume43
    Issue number7
    Publication statusPublished - 2010

    Cite this