Abstract
An on-line entropy control strategy was implemented for the wet end section of a pilot paper machine. Real-time tests were conducted to show the effectiveness of the modeling method. The method provided a stable and reliable solution to the robust proportional-integral-derivative (PID) control design problem.
Original language | English |
---|---|
Pages (from-to) | 134-139 |
Number of pages | 5 |
Journal | Measurement and Control |
Volume | 34 |
Issue number | 5 |
Publication status | Published - Jun 2002 |