Reliable method for calculating the center of rotation in parallel-beam tomography

NT Vo, M Drakopoulos, RC Atwood, C Reinhard

Research output: Contribution to journalArticlepeer-review

Abstract

High-throughput processing of parallel-beam X-ray tomography at synchrotron facilities is lacking a reliable and robust method to determine the center of rotation in an automated fashion, i.e. without the need for a human scorer. Well-known techniques based on center of mass calculation, image registration, or reconstruction evaluation work well under favourable conditions but they fail in cases where samples are larger than field of view, when the projections show low signal-to-noise, or when optical defects dominate the contrast. Here we propose an alternative technique which is based on the Fourier analysis of the sinogram. Our technique shows excellent performance particularly on challenging data.

© 2014 Optical Society of America
Original languageEnglish
Pages (from-to)19078-19086
Number of pages9
JournalOptics Express
Volume22
Issue number16
Early online date30 Jul 2014
DOIs
Publication statusPublished - 11 Aug 2014

Fingerprint

Dive into the research topics of 'Reliable method for calculating the center of rotation in parallel-beam tomography'. Together they form a unique fingerprint.

Cite this