TY - GEN
T1 - Simulation of late gadolinium enhancement cardiac magnetic resonance studies
AU - Tobon-Gomez, C.
AU - Sukno, F. M.
AU - Butakoff, C.
AU - Huguet, M.
AU - Frangi, A. F.
PY - 2010
Y1 - 2010
N2 - In this study we propose a pipeline for simulation of late gadolinium enhancement images. We used a modified version of the XCAT phantom to improve simulation realism. Modifications included the modeling of trabeculae and papillary muscles, and the increase of sublabels to resemble tissue intensity variability. Magnetic properties for each body tissue were sampled in three settings: from Gaussian distributions, combining Rayleigh-Gaussian distributions, and from Rayleigh distributions. Thirty-two simulated datasets were compared with 32 clinical datasets from infarcted patients. Histograms were obtained for five tissues: lung, pericardium, myocardium, blood and hyper-enhanced area. Real and simulated histograms were compared with the Chi-square dissimilarity metric (χ2) and Kullback-Leibler divergence (KL). The generated simulated images look similar to real images according to both metrics. Rayleigh and the Rayleigh-Gaussian models obtained comparable average results (respectively: χ2= 0.16± 0.12 and 0.18±0.11; KL=0.15±0.17 and 0.16±0.18).
AB - In this study we propose a pipeline for simulation of late gadolinium enhancement images. We used a modified version of the XCAT phantom to improve simulation realism. Modifications included the modeling of trabeculae and papillary muscles, and the increase of sublabels to resemble tissue intensity variability. Magnetic properties for each body tissue were sampled in three settings: from Gaussian distributions, combining Rayleigh-Gaussian distributions, and from Rayleigh distributions. Thirty-two simulated datasets were compared with 32 clinical datasets from infarcted patients. Histograms were obtained for five tissues: lung, pericardium, myocardium, blood and hyper-enhanced area. Real and simulated histograms were compared with the Chi-square dissimilarity metric (χ2) and Kullback-Leibler divergence (KL). The generated simulated images look similar to real images according to both metrics. Rayleigh and the Rayleigh-Gaussian models obtained comparable average results (respectively: χ2= 0.16± 0.12 and 0.18±0.11; KL=0.15±0.17 and 0.16±0.18).
UR - http://www.scopus.com/inward/record.url?scp=78650831322&partnerID=8YFLogxK
U2 - 10.1109/IEMBS.2010.5626854
DO - 10.1109/IEMBS.2010.5626854
M3 - Conference contribution
C2 - 21096359
AN - SCOPUS:78650831322
SN - 9781424441235
T3 - 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC'10
SP - 1469
EP - 1472
BT - 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC'10
T2 - 2010 32nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC'10
Y2 - 31 August 2010 through 4 September 2010
ER -