Surface characterization of SLActive dental implants.

Spiros Zinelis, Nick Silikas, Andrew Thomas, Karen Syres, George Eliades

    Research output: Contribution to journalArticlepeer-review

    742 Downloads (Pure)

    Abstract

    The aim of the study was to characterize the surface chemistry, hydration capacity, topography and roughness of the root part of a hydrophilic sandblasted and acid-etched titanium dental implant (SLActive). Implants as received (SAR), after water rinsing (SAW) and after ultrasonication in water (SAU) were subjected to x-ray photoelectron spectroscopy (XPS) elemental and binding state analysis. Scanning electron microscopy plus energy dispersive x-ray microanalysis (SEM/EDX), reflection Fourier transform infrared microspectroscopy (RFTIRM) and hydration/ dehydration cycling by environmental scanning electron microscopy (ESEM), were performed in SAR, whereas SAU implants were subjected to 3D-optical profilometry and SEM. For all the experiments, a conventional sandblasted and acid-etched implant (SLA ) of the same manufacturer was used as control. XPS showed lower mean C content in SAR than SLA, but not significantly different. In SAW, the C and O contents were increased. Significantly reduced C and increased Ti and O contents were found in SAU. Residual Na phases, other than NaCl, were traced in all SLActive groups. SAR demonstrated higher [-OH]/O2- ratio than SLA . EDX documented higher O, Na, Cl and lower Ti content in SAR. More -OH contributions were probed on SAR in comparison with SLA by RFTI RM. Ti-O peaks assigned to anatase, rutile and amorphous phases were found in both implant groups. The ESEM study revealed a full rehydration capacity in SAR, in contrast to SLA. No differences were found in the topography of SAU and SLA implant surfaces under the SEM. However, significantly greater values in spatial and functional roughness parameters were encountered in SAU. The increased surface hydroxylated titanium content and the greater spatial and functional roughness parameters, may explain the enhanced biological activity documented for SLActive in comparison with SLA.
    Original languageEnglish
    Pages (from-to)72-92
    Number of pages20
    JournalEuropean journal of esthetic dentistry: official journal of the European Academy of Esthetic Dentistry
    Volume7
    Issue number1
    Publication statusPublished - Mar 2012

    Fingerprint

    Dive into the research topics of 'Surface characterization of SLActive dental implants.'. Together they form a unique fingerprint.

    Cite this