System test of the ATLAS muon spectrometer in the H8 beam at the CERN SPS

C. Adorisio, G. Aielli, T. Alexopoulos, P. Amaral, C. Amelung, G. Avolio, R. Avramidou, P. Bagnaia, M. Barisonzi, M. Barone, F. Bauer, I. Benhammou, J. Bensinger, M. Beretta, G. Bobbink, A. Borisov, H. Boterenbrood, I. Boyko, S. Braccini, P. BranchiniS. Bressler, V. Canale, M. Caprio, R. Cardarelli, G. Cataldi, F. Cerutti, J. Chapman, G. Chelkov, G. Chiodini, G. Ciapetti, M. Cirilli, D. Dedovich, M. Della Pietra, D. Della Volpe, R. De Asmundis, A. Di Ciaccio, A. Di Domenico, A. Di Simone, J. Dubbert, E. Etzion, R. Fakhrutdinov, S. Falciano, R. Ferrari, A. Formica, C. Fukunaga, G. Gaudio, E. Gazis, P. F. Giraud, E. Gorini, F. Grancagnolo, J. Gregory, H. Groenstege, C. Guyot, A. Harel, R. Hart, K. Hashemi, S. Hassani, S. Horvat, R. Ichimiya, P. Iengo, M. Ikeno, P. Ioannou, M. Iodice, M. Ishino, Y. Kataoka, A. Konig, O. Kortner, C. Kourkoumelis, A. Kozhin, H. Kroha, Z. Krumshteyn, H. Kurashige, F. Lacava, E. Lancon, A. Lanza, J. F. Laporte, D. Lellouch, D. Levin, L. Levinson, R. Lifshitz, F. Linde, C. Luci, N. Lupu, G. Maccarrone, T. Maeno, K. Mair, S. Maltezos, A. Manz, E. Meoni, G. Mikenberg, P. Mockett, S. Mohrdieck-Moeck, K. Nagano, K. Nikolaev, R. Nikolaidou, A. Nisati, H. Nomoto, D. Orestano, S. Palestini, E. Pasqualucci, F. Pastore, R. Perrino, F. Petrucci, G. Polesello, A. Policicchio, D. Pomarede, P. Ponsot, L. Pontecorvo, M. Primavera, F. Rauscher, D. Rebuzzi, R. Richter, S. Rosati, J. Rothberg, H. Sakamoto, R. Santonico, O. Sasaki, A. Schricker, G. Schuler, P. Schune, S. Spagnolo, R. Spiwoks, A. Staude, G. Stavropoulos, Y. Sugaya, S. Tanaka, S. Tarem, R. Thun, I. Trigger, G. Tsipolitis, C. Valderanis, P. Valente, W. Vandelli, R. Vari, S. Veneziano, J. Vermeulen, T. Wengler, P. Werneke, T. Wijnen, M. Wolter, M. Woudstra, Y. Yasu, P. F. Zema, Z. Zhao, A. Zhemchugov, B. Zhou, N. van Eldik, H. van der Graaf

    Research output: Contribution to journalArticlepeer-review

    Abstract

    We describe a system test of the ATLAS muon spectrometer performed at the H8 beam line of the CERN Super-Proton-Synchrotron (SPS) during 2003. The setup includes one barrel tower made of six Monitored Drift Tube chambers equipped with an alignment system and four Resistive Plate Chambers, and one end-cap octant consisting of six end-cap MDT equipped with an alignment system and one triplet and two doublets of Thin Gap Chambers. Many system aspects of the muon spectrometer have been studied with this setup, from the performance of the precision and trigger chambers to the capability to align the precision chambers at the level of a few tens of micrometers and to operate the muon trigger at the crossing frequency of the LHC. © 2008 Elsevier B.V.
    Original languageEnglish
    Pages (from-to)232-254
    Number of pages22
    JournalNuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
    Volume593
    Issue number3
    DOIs
    Publication statusPublished - 11 Aug 2008

    Keywords

    • ATLAS muon spectrometer
    • CERN
    • SPS
    • Test beam

    Fingerprint

    Dive into the research topics of 'System test of the ATLAS muon spectrometer in the H8 beam at the CERN SPS'. Together they form a unique fingerprint.

    Cite this