Target coverage in image-guided stereotactic body radiotherapy of liver tumors

Wouter Wunderink, Alejandra Méndez Romero, Eliana M Vásquez Osorio, Hans C J de Boer, René P Brandwijk, Peter C Levendag, Ben J M Heijmen

Research output: Contribution to journalArticlepeer-review

Abstract

PURPOSE: To determine the effect of image-guided procedures (with computed tomography [CT] and electronic portal images before each treatment fraction) on target coverage in stereotactic body radiotherapy for liver patients using a stereotactic body frame (SBF) and abdominal compression. CT guidance was used to correct for day-to-day variations in the tumor's mean position in the SBF.

METHODS AND MATERIALS: By retrospectively evaluating 57 treatment sessions, tumor coverage, as obtained with the clinically applied CT-guided protocol, was compared with that of alternative procedures. The internal target volume-plus (ITV(+)) was introduced to explicitly include uncertainties in tumor delineations resulting from CT-imaging artifacts caused by residual respiratory motion. Tumor coverage was defined as the volume overlap of the ITV(+), derived from a tumor delineated in a treatment CT scan, and the planning target volume. Patient stability in the SBF, after acquisition of the treatment CT scan, was evaluated by measuring the displacement of the bony anatomy in the electronic portal images relative to CT.

RESULTS: Application of our clinical protocol (with setup corrections following from manual measurements of the distances between the contours of the planning target volume and the daily clinical target volume in three orthogonal planes, multiple two-dimensional) increased the frequency of nearly full (> or = 99%) ITV(+) coverage to 77% compared with 63% without setup correction. An automated three-dimensional method further improved the frequency to 96%. Patient displacements in the SBF were generally small (< or = 2 mm, 1 standard deviation), but large craniocaudal displacements (maximal 7.2 mm) were occasionally observed.

CONCLUSION: Daily, CT-assisted patient setup may substantially improve tumor coverage, especially with the automated three-dimensional procedure. In the present treatment design, patient stability in the SBF should be verified with portal imaging.

Original languageEnglish
Pages (from-to)282-90
Number of pages9
JournalInternational journal of radiation oncology, biology, physics
Volume68
Issue number1
DOIs
Publication statusPublished - 1 May 2007

Keywords

  • Artifacts
  • Humans
  • Immobilization
  • Liver Neoplasms
  • Movement
  • Radiography, Interventional
  • Radiosurgery
  • Respiration
  • Retrospective Studies
  • Tomography, X-Ray Computed
  • Journal Article

Research Beacons, Institutes and Platforms

  • Manchester Cancer Research Centre

Fingerprint

Dive into the research topics of 'Target coverage in image-guided stereotactic body radiotherapy of liver tumors'. Together they form a unique fingerprint.

Cite this