The structural behaviour of steel columns during a compartment fire in a multi-storey braced steel-frame

C. G. Bailey, D. B. Moore, T. Lennon

Research output: Contribution to journalArticlepeer-review

Abstract

Test results from a compartment fire in the eight-story steel-framed building at Cardington, have shown that the columns, which were heavily fire protected, were subjected to significant induced moments. These moments, which are ignored in existing fire design methods, were caused by the connected heated steel beams, which were unprotected, expanding and displacing the columns laterally. This behaviour was confirmed from the measured test displacements and computer modelling. Proposals for future research work are presented to enable design guidance to be developed to ensure stability of columns, when subjected to these moments during a fire.
Original languageEnglish
Pages (from-to)137-157
Number of pages20
JournalJournal of Constructional Steel Research
Volume52
Issue number2
DOIs
Publication statusPublished - Nov 1999

Keywords

  • Columns
  • Fire
  • Full scale test
  • Stability
  • Thermal expansion

Fingerprint

Dive into the research topics of 'The structural behaviour of steel columns during a compartment fire in a multi-storey braced steel-frame'. Together they form a unique fingerprint.

Cite this