    Abstract

    This is Part II of a two part paper dealing with the current state of knowledge of the fire-safe structural design and construction of unbonded post-tensioned (UPT) flat plate concrete structures. Part I provided detailed results of nineteen transient high temperature stress relaxation tests on restrained UPT tendons of realistic length and parabolic longitudinal profiles. Experimentation identified several credible concerns for UPT concrete structures in fire, most notably the potential for premature tendon rupture due to localized heating, which may result from a number of possible causes in a real structure. The real world response of continuous UPT tendons both during and after heating is largely unknown, and is dependent on factors which are not currently accounted for either in standard fire tests or by available prescriptive design guidance. This second part of the paper presents and applies a numerical model to predict the time-temperaturestress-strength interdependencies of stressed UPT tendons under localized transient heating, as may be experienced by tendons in a real concrete building in a real fire. The model is used, along with previously developed and validated computational models for heat transfer and prestress relaxation in UPT tendons, to assess existing prescriptive concrete cover requirements for UPT slabs. It is shown that localized heating of UPT tendons is likely to induce premature tendon rupture during fire, and that current prescriptive code procedures based on concrete cover alone are, in general, insufficient to prevent this. Based on the data presented it appears that minimum code prescribed concrete covers for UPT structures require revision if premature tendon rupture during fire is to be avoided.
    Original languageEnglish
    Pages (from-to)155-171
    Number of pages16
    JournalJournal of Structural Fire Engineering
    Volume2
    Issue number3
    Publication statusPublished - 1 Sept 2011

    Keywords

    • Concrete
    • Concrete cover
    • Fire endurance testing
    • High temperature creep
    • Post-tensioned slabs
    • Prestressing steel
    • Spalling
    • Stress relaxation
    • Unbonded construction